Hebei Kaixiang Electrical Technology Co., Ltd
Contact Now

Cabinet Power Bank 3546 KVA Resistance Load Bank For Diesel Generator

Brand Name : Kaixiang

Model Number : AC480 - 3546KVA

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : negotiable

Payment Terms : Western Union, L/C, T/T

Supply Ability : 40 Sets / Month

Delivery Time : Within 32 working days

Packaging Details : Packaged in container

Model : AC480V - 3546KVA

Rated power : 3546 KVA

Voltage : AC480V

Colour : Grey surface

Duty cycle : Continous working

Relative Humidity : ≤95%

Contact Now

Cabinet Power Bank 3546 KVA 3 Phase Load Banks For Diesel Generator

Introduction

AC480 - 3546KVA 3 Phase Load Bank consist of dry load module and auto control module, test load and output power of generators, the test including setting, fluctuation,transient load/unload,recorded wave analysis,harmonic analysis,testing the static parameter and dynamic parameter

Applications
Application

1 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set, UPS real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

2 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

3 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set, UPS etc.

Technical specification

System Parameter
Rating voltage/frequency

480V, 3 phase 3 wire, 60HZ

208V, 3 phase 3 wire, 60HZ

Max Load Power

480V,3phase 3wire, 60HZ, star coupling “Y”

Apparent Power: 3546KVA

Resistive Load: 2836kW

Inductive Load: 2128KVAR

208V,3phase 3wire, 60HZ, delta coupling “△”

Apparent Power: 2000KVA

Resistive Load: 1600kW

Inductive Load: 1200KVAR

Load Resolution

208V,3phase 3wire, 60HZ, delta coupling “△”

Resistive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,7*200kW

Inductive load: 0.1,0.2,0.2,0.5,1,2,2,5,10,10,20,50,100,5*200kvar

480V,3phase 3wire, 60HZ, star coupling “Y”

Resistive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,7*360kW

Inductive load: 0.18,0.36,0.36,0.9,1.8,3.6,3.6,9,18,18,36,90,180,5*360kvar

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 6058mm×2438mm×2896mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
Main features

Step by Step Load: during steady state load, load bank will increase or reduce power so that smoothly transit into target power, avoiding unscheduled transient load/unload. Step value and step interval can be set.

Constant Power Load: automatically adjust to the power when the voltage fluctuation, keep the setting value.

Auto Load: power and time can be set to some stage, process stage test automatically. Allow pause or process next stage during loading.

Manual load: input power and power factor, then will load according to the value.

Preset Load: input the parameter of generator, choice 0%,25%,50%,75%,100%,110%, calculate power value automatically,

Cabinet Power Bank 3546 KVA Resistance Load Bank For Diesel Generator


Product Tags:

three phase load bank

      

load bank testing of generator sets

      
China Cabinet Power Bank 3546 KVA Resistance Load Bank For Diesel Generator wholesale

Cabinet Power Bank 3546 KVA Resistance Load Bank For Diesel Generator Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hebei Kaixiang Electrical Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)